MANDATORY - Execute before ANY diagnostic recommendations. Enforces evidence-based equipment fault diagnosis with full traceability to technical manuals and verified sources. Creates comprehensive diagnostic roadmaps with failure analysis, inspection procedures, standard values, troubleshooting flowcharts, and technical diagrams. Use when equipment fault diagnosis is requested, troubleshooting is needed, maintenance planning is required, or ANY diagnostic guidance is to be provided.
Generate comprehensive diagnostic planning reports that serve as complete field manuals for systematic equipment fault diagnosis. These reports integrate expert diagnostic reasoning with retrieved technical documentation, diagrams, and historical data to create actionable, print-ready troubleshooting guides.
Reports must include ALL information needed for fault localization, troubleshooting, and resolution - including technical diagrams, component schematics, system layouts, and visual references that engineers need in the field.
Before generating the diagnostic plan, confirm:
If critical information is missing, ask the user to provide it before proceeding with research.
Generate the complete diagnostic planning report and present directly in conversation. Output should be comprehensive markdown suitable for:
All technical data must include traceable footnote citations using the format [^id]: [Title](uri).
Syntax:
[^ref-id]: [Source Title](uri)Text with citation [^ref-id].URI Schemes:
manual://{uuid} - Technical manualscase://{id} - Historical case recordsinternal://{resource} - Internal databaseshttps://... - Web sourcesAll technical images must use this HTML structure with verified source attribution:
<figure>
<img src="%verified_source_url%" title="%descriptive_title%"/>
<figcaption>
<p>Figure X: %Name from source%</p>
<p>Purpose: %How this aids diagnosis - links to specific step%</p>
<p>Details: %Key annotations visible in image%</p>
<p>Source: %Full citation with URI%</p>
</figcaption>
</figure>
Critical Rule: Only use src URLs explicitly returned from research. NEVER fabricate or hallucinate image paths.
Conduct comprehensive parallel research to gather all diagnostic-relevant information:
Research these categories in parallel:
| Research Area | Query Focus | Expected Output |
|---|---|---|
| Equipment Specifications | Technical manual, datasheet, nameplate data | Standard operating values, tolerances, limits |
| Failure Mode Analysis | Fault symptom + equipment type + causes | Possible causes, mechanisms, occurrence frequency |
| Troubleshooting Procedures | Manufacturer diagnostic guides, SOPs | Step-by-step inspection sequences, decision trees |
| Historical Cases | Similar equipment + fault + case study | Resolved incidents, effective solutions, lessons |
| Technical Diagrams | Schematics, system layouts, component drawings | Visual references for diagnosis and repair |
| Standards & Codes | Industry standards for equipment class | Inspection criteria, acceptance tolerances |
| Category | Query Pattern |
|---|---|
| Equipment Manual | {Model} technical manual specifications |
| Parameters | {Model} {parameter} standard value tolerance |
| Failure Knowledge | {Equipment type} {symptom} causes failure mode |
| Procedures | {Manufacturer} {model} troubleshooting procedure |
| Diagrams | {Model} schematic diagram system layout |
| Cases | {Model} {fault} case study field report |
| Standards | {Equipment type} inspection standard {ISO/GB} |
Combine retrieved information:
Thoroughly analyze retrieved information before proceeding:
Identify Conflicts and Inconsistencies:
| Aspect | Check | Action if Conflict Found |
|---|---|---|
| Parameter values | Multiple sources claiming different specs | Flag for verification; prioritize manufacturer manual |
| Failure causes | Contradictory explanations for same symptom | Note both theories; check historical case frequency |
| Procedures | Different manufacturers suggest different steps | Document both; note equipment-specific applicability |
| Standards | Industry vs manufacturer tolerance differences | Highlight both; explain context of each |
Completeness Assessment:
Iterative Research Decision: If gaps or conflicts exist, judge whether additional searches are needed:
Rule: Exhaust reasonable search avenues before concluding research. Better to over-search than under-search.
Execute searches in this order to maximize source reliability:
| Priority | Source Type | Tools/Methods | Rationale |
|---|---|---|---|
| 1 | Technical Manuals | Knowledge base queries, MCP document retrieval, manual://{uuid} sources | Authoritative manufacturer data, equipment-specific |
| 2 | Internal Knowledge Base | Case databases, maintenance records, organizational documentation | Proprietary data, organizational context, historical precedents |
| 3 | Web Resources | Search APIs (Tavily, web search, documentation sites) | Supplementary, cross-verification, filling gaps only |
Rule: Always attempt primary sources (manuals/knowledge base) before web search. Web results should be used for filling gaps, not as primary evidence. All web findings must be cross-referenced with manufacturer data when possible.
Before generating the final report, systematically organize all collected information:
Create a Structured Outline:
## Report Outline
### Key Findings Summary
- Equipment: [Model, Manufacturer, Key Specs]
- Fault: [Symptom description, observed behavior]
- Primary Hypotheses: [Cause 1 - evidence], [Cause 2 - evidence]...
- Confidence Level: [High/Medium/Low based on source quality]
### Supporting Evidence by Section
- Section 2 (Equipment): Specs from [^manual-1], diagrams from [^manual-2]...
- Section 3 (Failure Analysis): Causes ranked by [^case-1], [^case-2]...
- Section 4 (Inspection): Procedures from [^manual-1]...
- [Continue for each section]
### Reference Materials Inventory
| Source ID | Document | Key Content | Target Section |
|-----------|----------|-------------|----------------|
| [^manual-1] | SY215C Technical Manual Ch. 3 | Hydraulic specs | Section 2, 5 |
| [^case-1] | Case #2023-0156 Overheat | Resolution: pump replacement | Section 3, 8 |
| [std-1] | ISO 10816 Vibration | Acceptable vibration limits | Section 5 |
Conflict Documentation:
| Topic | Source A | Source B | Resolution Decision |
|---|---|---|---|
| [e.g., Operating pressure] | Manual says 25MPa | Case file mentions 28MPa | Use manual value [^manual-1], note case anomaly [^case-2] |
Gap List for Section 13:
Stop and Review: Confirm outline covers all user requirements and collected data before proceeding to Step 3.
Create a detailed, field-ready report using the outline from Step 2. Verify each section against your outline:
At the start of the report, create a ## References section listing all sources found during research using the citation format defined in Document Conventions.
Required Format (must follow exactly):
## References
[^manual-1]: [SY215C Hydraulic System Specifications, Ch. 3 Operating Parameters](manual://a1b2c3d4-e5f6-7890-abcd-ef1234567890)
[^manual-2]: [CP-2000 Technical Manual, Section 4.2 - Bearing Installation](manual://b2c3d4e5-f6a7-8901-bcde-f23456789012)
[^case-1]: [Excavator Overheat Case #2023-0156 - Root Cause Analysis](case://2023-0156)
[^case-2]: [Hydraulic Pump Failure Field Report #2024-0089](case://2024-0089)
[^std-1]: [ISO 10816-1:1995 Mechanical Vibration - Evaluation Standards](https://www.iso.org/standard/10816-1.html)
[^web-1]: [Hydraulic System Troubleshooting Guide](https://example.com/hydraulic-guide) - Cross-reference only
Format Rules:
[^manual-{n}], [^case-{n}], [^std-{n}], [^web-{n}] for clarity[Section Name, Document Name] or [Case #{ID} - Brief Description]Process:
Verification Checklist:
[^type-number] naming conventionIf no sources are found, omit Section 0 entirely (do not create empty section).
2.1 Equipment Specifications
| Parameter | Specification | Source |
|---|---|---|
| Model/Type | ||
| Manufacturer | ||
| Rated capacity | ||
| Operating limits | ||
| Key components |
2.2 System Overview
2.3 Technical Diagrams Include all relevant diagrams with proper figure formatting:
<figure>
<img src="%image_url%" title="%image_title%"/>
<figcaption>
<p>Figure X: %figure_name%</p>
<p>%detailed_diagnostic_purpose%</p>
<p>%annotation_legend_details%</p>
<p>Source: %citation%</p>
</figcaption>
</figure>
Required diagrams (when available):
| Cause | Probability | Failure Mechanism | Key Indicators | Evidence Source |
|---|---|---|---|---|
| [Cause 1] | High/Med/Low | Technical explanation of cause-effect | Parameters/symptoms to check | [Manual/Case ref] |
| [Cause 2] | High/Med/Low | Technical explanation of cause-effect | Parameters/symptoms to check | [Manual/Case ref] |
For each cause include:
4.1 Inspection Checklist
| Step | Inspection Item | Priority | Procedure | Normal Value | Tools Required | Reference |
|---|---|---|---|---|---|---|
| 1 | Critical/High/Med/Low | Detailed procedure | Expected range | Specific tools | [Manual/Diag. ref] |
4.2 Detailed Inspection Procedures
For each critical inspection step, provide:
4.3 Component Location Visuals
Include annotated diagrams showing:
5.1 Operating Parameters Reference Table
| Parameter | Normal Range | Warning Threshold | Critical Threshold | Unit | Measurement Point | Source |
|---|---|---|---|---|---|---|
5.2 Component Specifications
| Component | Specification | Tolerance | Unit | Inspection Method | Source |
|---|---|---|---|---|---|
5.3 Acceptance Criteria
6.1 Diagnostic Tools
| Tool | Specification | Purpose | Source Reference |
|---|---|---|---|
| Model/accuracy range | What to measure | [Manual ref] |
6.2 Hand Tools and Equipment
| Tool | Size/Specification | Application |
|---|---|---|
6.3 Consumables and Spares
| Item | Part Number | Quantity | Application |
|---|---|---|---|
6.4 Safety Equipment
6.5 Reference Documents Required On-Site
7.1 Decision Flowchart
graph TD
A["Fault Detected"] --> B{"Check: Parameter"}
B -->|"Normal"| C{"Check: Parameter"}
B -->|"Abnormal"| D["Action: Inspect"]
...
Flowchart must include:
7.2 Fault Tree Analysis (if applicable)
graph TD
Top["Top Event: Fault"]
Top --> OR1["OR Gate"]
OR1 --> AND1["AND Gate"]
OR1 --> Cause1["Cause"]
AND1 --> Cause2["Cause"]
AND1 --> Cause3["Cause"]
7.3 Diagnostic Decision Table
| Symptom/Reading | Likely Cause | Next Step | Reference |
|---|---|---|---|
8.1 Corrective Actions by Cause
| Cause | Corrective Action | Procedure Reference | Safety Notes |
|---|---|---|---|
8.2 Repair Procedures
8.3 Verification and Testing
Include all relevant technical images using the figure format defined in Document Conventions.
Image categories to include when available:
A. Glossary of Terms B. Units Conversion Table C. Emergency Contacts / Escalation Procedures D. Document Revision History
All factual claims must include citations using the format defined in Document Conventions.
Requirements:
Purpose: Transparently document missing or unavailable information that may affect diagnostic accuracy or completeness.
Critical Rule: Explicitly list ALL information that was searched but not found. This section is essential for assessing report reliability and identifying areas requiring field verification or expert consultation.
| Category | Requested Information | Search Attempted | Gap Impact | Recommended Action |
|---|---|---|---|---|
| Equipment Specifications | [Specific missing spec] | [Sources searched] | [High/Med/Low] | [e.g., Verify on-site nameplate] |
| Operating Parameters | [Missing parameter] | [Sources searched] | [High/Med/Low] | [e.g., Measure during inspection] |
| Troubleshooting Procedures | [Missing procedure] | [Sources searched] | [High/Med/Low] | [e.g., Contact manufacturer] |
| Technical Diagrams | [Missing diagram type] | [Sources searched] | [High/Med/Low] | [e.g., Request from service dept] |
| Historical Cases | [Missing case data] | [Sources searched] | [High/Med/Low] | [e.g., Check field service records] |
Gap Categories to Check:
Impact Assessment:
## Diagnostic Planning Limitations
This diagnostic plan was developed based on the following constraints:
### Data Availability
- [List specific data gaps from table above]
- Sources consulted: [List databases, manuals, resources searched]
- Search date: [Timestamp]
### Impact on Diagnostic Reliability
[Describe how gaps may affect the diagnostic process]
### Field Verification Required
The following items MUST be verified during on-site inspection due to missing documentation:
1. [Item requiring field measurement/verification]
2. [Item requiring physical inspection]
### Escalation Triggers
If the following unavailable information becomes critical during diagnosis:
- [Gap 1]: Escalate to [manufacturer/service provider]
- [Gap 2]: Consult [expert/resource]
Include at end of Section 12:
---
**Field Engineer Acknowledgment**:
I understand that this diagnostic plan has the following information gaps:
- [Gap summary 1]
- [Gap summary 2]
I will verify these items during field inspection and adjust the diagnostic approach as needed.
Engineer Signature: _______________ Date: _______
Generate the final diagnostic planning report containing:
Research must be conducted for:
Image Handling: All images must be from verified sources. See Document Conventions for detailed requirements. If no image is retrieved from sources, omit the <figure> tag entirely and describe the visual in text.