Production facilities skill for sizing separators, glycol dehydration systems, and compression equipment. Calibrated for Appalachian gas and oil production.
Important: These are preliminary sizing equations for scoping and conceptual design. Final equipment sizing requires detailed process simulation (HYSYS, ProMax, or equivalent) with full fluid compositions and phase behavior.
import math
def separator_gas_capacity_mmscfd(D_ft, L_eff_ft, P_psia, T_f,
gas_sg=0.65, z=0.9,
Ks=0.25, separator_type="vertical"):
"""
Gas handling capacity based on droplet settling (Souders-Brown).
Ks = 0.25 ft/s vertical, 0.40 ft/s horizontal (typical gas-liquid)
D_ft: vessel internal diameter (ft)
L_eff_ft: effective vessel length (ft) -- use D for vertical
P_psia: operating pressure
T_f: operating temperature (°F)
Returns: gas capacity (MMscf/day)
"""
T_R = T_f + 459.67
# Gas density at operating conditions
rho_g = (28.97 * gas_sg * P_psia) / (10.73 * T_R * z) # lb/ft3
# Water density ~62.4; oil ~50–55; use water as conservative
rho_l = 62.4
# Terminal droplet velocity
v_t = Ks * math.sqrt((rho_l - rho_g) / rho_g) # ft/s
# Cross-sectional area for gas flow
if separator_type.lower() == "vertical":
A_g_ft2 = math.pi / 4.0 * D_ft**2
else:
# Horizontal: assume gas occupies top half
A_g_ft2 = math.pi / 8.0 * D_ft**2
# Gas flow at operating conditions (ft3/s)
Q_op_ft3_s = v_t * A_g_ft2
# Convert to MMscfd (standard conditions: 14.7 psia, 60°F)
Q_scf_s = Q_op_ft3_s * (P_psia / 14.7) * (520.0 / T_R) * z
return Q_scf_s * 86400.0 / 1e6
def separator_liquid_volume_bbl(q_liquid_bpd, retention_time_min=1.5):
"""
Required liquid volume for retention time.
retention_time_min: 1–2 min two-phase; 3–5 min three-phase (oil-water sep)
Returns: liquid volume needed (bbl)
"""
return q_liquid_bpd * retention_time_min / (24.0 * 60.0)
def separator_diameter_from_liquid(V_liquid_bbl, L_D_ratio=3.0,
liquid_fill_frac=0.5):
"""
For horizontal separators: V_vessel = pi/4 * D^2 * L
L = L_D_ratio * D; V_liquid = liquid_fill_frac * V_vessel
Returns: D (ft), L (ft)
"""
V_ft3 = V_liquid_bbl * 5.615
V_vessel_ft3 = V_ft3 / liquid_fill_frac
# V = pi/4 * D^2 * L_D * D = pi/4 * L_D * D^3
D_ft = (V_vessel_ft3 / (math.pi / 4.0 * L_D_ratio))**(1.0/3.0)
L_ft = L_D_ratio * D_ft
return {"D_ft": D_ft, "L_ft": L_ft, "D_in": D_ft * 12.0}
def three_phase_retention_check(q_oil_bpd, q_water_bpd,
api_oil=35, T_f=80.0,
retention_oil_min=5.0,
retention_water_min=10.0):
"""
Stokes' law settling time for water droplets in oil.
Minimum retention for adequate oil-water separation.
Higher API or temperature = lower viscosity = faster settling = less time needed.
Returns: required liquid volumes (bbl).
"""
V_oil_bbl = q_oil_bpd * retention_oil_min / (24.0 * 60.0)
V_water_bbl = q_water_bpd * retention_water_min / (24.0 * 60.0)
return {"V_oil_bbl": V_oil_bbl, "V_water_bbl": V_water_bbl,
"V_total_liquid_bbl": V_oil_bbl + V_water_bbl}
def stage_separation_pressures(P_wellhead_psia, n_stages=3,
P_final_psia=25.0):
"""
Optimal intermediate separator pressures for maximum liquid recovery.
Equal pressure ratios: r = (P_wellhead / P_final)^(1/n_stages)
P_wellhead_psia: first separator operating pressure
P_final_psia: stock tank or sales line pressure
Returns: list of separator pressures (psia)
"""
ratio = (P_wellhead_psia / P_final_psia)**(1.0 / n_stages)
pressures = []
P = P_wellhead_psia
for i in range(n_stages):
pressures.append(round(P, 0))
P = P / ratio
return pressures
# Example: 1200 psia wellhead, 3 stages, 25 psia stock tank
# Pressures: [1200, 195, 32, 25] (approx equal ratios ~6.2x each stage)
Stage separation benefits:
def teg_dew_point_depression(contact_temp_f, circulation_rate_gal_lb,
teg_concentration_wt_frac=0.995):
"""
Approximate dew point depression from TEG contactor.
Uses Worley (1967) correlation: delta_T ~ f(TEG concentration, L/G ratio)
contact_temp_f: contactor temperature (°F) -- typically 80–100°F
circulation_rate_gal_lb: TEG circulation (gal TEG / lb H2O absorbed)
typical range: 1.0–1.5 gal/lb for delta_T depression of 40–80°F
teg_concentration_wt_frac: 0.995–0.999 (99.5–99.9% TEG by weight)
Returns: approximate dew point depression (°F)
"""
# Simplified linear approximation to Worley chart
# At L/G = 1.0 gal/lb and 99.5% TEG: depression ~ 50°F
# At L/G = 1.5 gal/lb: ~ 70°F
base_depression = 50.0
lg_factor = (circulation_rate_gal_lb - 1.0) * 40.0
conc_factor = (teg_concentration_wt_frac - 0.995) * 2000.0
return base_depression + lg_factor + conc_factor
def teg_circulation_rate(water_content_in_lb_mmscf,
water_content_out_lb_mmscf,
gas_rate_mmscfd,
lg_ratio_gal_per_lb=1.2):
"""
Water absorbed = (Win - Wout) * gas_rate (lb/day)
TEG rate = water_absorbed * L/G ratio (gal/day)
water_content: lb H2O per MMscf of gas (from water content chart or calc)
lg_ratio: typically 1.0–1.5 gal TEG / lb H2O
"""
water_removed_lb_day = (water_content_in_lb_mmscf - water_content_out_lb_mmscf) * gas_rate_mmscfd
teg_rate_gpd = water_removed_lb_day * lg_ratio_gal_per_lb
return {"water_removed_lb_day": water_removed_lb_day,
"teg_rate_gpd": teg_rate_gpd,
"teg_rate_gph": teg_rate_gpd / 24.0}
def teg_reboiler_duty_mmbtu_day(teg_rate_gpd, duty_per_gal=800.0):
"""
Approximate reboiler heat duty.
duty_per_gal: BTU per gallon of TEG circulated
Typical: 600–1200 BTU/gal (lower for efficient contactors)
Returns: reboiler duty (MMBtu/day)
"""
return teg_rate_gpd * duty_per_gal / 1e6
TEG system reference:
| Parameter | Typical Value | Notes |
|---|---|---|
| TEG purity (lean) | 99.0–99.95 wt% | Higher = better depression |
| Reboiler temp | 375–400°F | Max 400°F to avoid TEG degradation |
| Contactor stages | 3–8 trays or 1–2 packing beds | More stages = better contact |
| L/G ratio | 1.0–1.5 gal/lb | Minimum 1.0; diminishing returns above 2.0 |
def compression_horsepower(Q_mmscfd, T_suction_f, P_suction_psia,
P_discharge_psia, k=1.27, z=0.9, eff=0.75):
"""
Adiabatic (isentropic) compression horsepower.
HP = (k / (k-1)) * (Z*T_s/528) * (P_d/P_s)^((k-1)/k) - 1) * Q * C
C = 0.0857 for Q in MMscfd, T in °R, P in psia -> HP in bhp
k = Cp/Cv: 1.27 natural gas (approx), 1.28–1.35 rich gas
eff: overall isentropic efficiency (0.70–0.80 typical reciprocating)
"""
T_R = T_suction_f + 459.67
r = P_discharge_psia / P_suction_psia
exponent = (k - 1.0) / k
HP_ideal = 0.0857 * (k / (k - 1.0)) * (z * T_R / 520.0) * (r**exponent - 1.0) * Q_mmscfd
return HP_ideal / eff
def compression_ratio(P_suction_psia, P_discharge_psia):
"""r = P_d / P_s -- keep < 4.0 per stage (< 3.5 for reciprocating)"""
return P_discharge_psia / P_suction_psia
def compression_stages_needed(P_suction_psia, P_discharge_psia,
max_ratio_per_stage=3.5):
"""Minimum stages for given overall ratio and max ratio per stage."""
import math
total_ratio = P_discharge_psia / P_suction_psia
return math.ceil(math.log(total_ratio) / math.log(max_ratio_per_stage))
def discharge_temperature(T_suction_f, P_suction_psia, P_discharge_psia,
k=1.27, z=0.9):
"""
T_d = T_s * (P_d/P_s)^((k-1)/k) (isentropic, ideal gas)
Returns: discharge temperature (°F)
For reciprocating: actual T_d ~20–30°F higher due to heat of compression.
Intercooling required when T_d > 300°F (typical limit).
"""
T_R = T_suction_f + 459.67
r = P_discharge_psia / P_suction_psia
T_d_R = T_R * r**((k - 1.0) / k)
return T_d_R - 459.67
def backpressure_deliverability_ratio(P_res_psia, P_wf_orig_psia,
P_wf_new_psia, n=0.8):
"""
Simplified backpressure equation for gas wells:
q2/q1 = (P_res^2 - P_wf2^2)^n / (P_res^2 - P_wf1^2)^n
n: backpressure exponent (0.5 turbulent to 1.0 laminar)
Returns: ratio of new rate to original rate
"""
num = (P_res_psia**2 - P_wf_new_psia**2)**n
den = (P_res_psia**2 - P_wf_orig_psia**2)**n
return num / den
def production_loss_from_backpressure(q_orig_mscfd, P_res_psia,
P_surface_orig_psia,
P_surface_new_psia,
tubing_gradient_psi_ft=0.1,
depth_ft=7500.0, n=0.8):
"""
Estimate production rate change when surface pressure changes.
Converts surface backpressure to flowing BHP change.
"""
P_wf_orig = P_surface_orig_psia + tubing_gradient_psi_ft * depth_ft
P_wf_new = P_surface_new_psia + tubing_gradient_psi_ft * depth_ft
ratio = backpressure_deliverability_ratio(P_res_psia, P_wf_orig, P_wf_new, n)
return {"q_new_mscfd": q_orig_mscfd * ratio, "ratio": ratio,
"delta_q_mscfd": q_orig_mscfd * (ratio - 1.0)}
## Surface Facilities Design — [Field / Well Pad]
**Gas rate:** X.X MMscfd | **Liquid rate:** XXX bbl/day | **WOR:** X.X
### Separator Sizing
| Vessel | Type | Size | Operating P (psia) | Gas cap. (MMscfd) | Liquid vol (bbl) |
|--------|------|------|-------------------|-------------------|-----------------|
| First stage | H/V | XX" x XX'-0" | | | |
| Second stage | | | | | |
### Dehydration System
| Parameter | Value |
|-----------|-------|
| Water content in (lb/MMscf) | |
| Water content out (lb/MMscf) | |
| TEG rate (gal/hr) | |
| Reboiler duty (MMBtu/day) | |
| Expected dew point depression (°F) | |
### Compression
| Stage | Suction P (psia) | Discharge P (psia) | Ratio | HP (bhp) | T_d (°F) |
|-------|-----------------|-------------------|-------|---------|---------|
| 1 | | | | | |
| 2 | | | | | |
### Backpressure Sensitivity
| Wellhead P (psia) | Rate (Mscf/d) | Change vs. base |
|-------------------|--------------|----------------|
| | | |
| Condition | Cause | Action |
|---|---|---|
| Separator undersized | Gas rate > capacity | Increase D or use horizontal vessel |
| TEG rate very high | Low L/G or wet gas | Verify water content; check inlet separator |
| Discharge T > 300°F | High ratio, hot suction | Add intercooler; split into more stages |
| Production loss > 20% | High backpressure relative to reservoir P | Evaluate compression or larger gathering pipe |